Order no.: 0172550

PA-1960

Order no.: 0172550

PA-1960

High-power mono PA amplifier
  • 1 x 960 W
  • Additional, adjustable priority input with switchable priority function
  • 100 V slave input for inserting the amplifier into a 100 V speaker line
  • Switchable 400 Hz high-pass filter 6 dB/oct.
  • 2 insertion facilities on the rear panel for optional modules with the following features:
  • PA-6FD: fault detection module
  • PA-6FM: fault monitoring module
  • Connection for external on/off switch (remote start)
  • Temperature-controlled fan, continuously adjustable
  • LED indication for fault, protect, clip, signal, priority
  • Mains operation or 24 V emergency power operation
Manufacturer information:
MONACOR INTERNATIONAL GmbH & Co. KG
Konsul-Smidt-Str. 68
28217 Bremen
Germany
info@monacor.com
Safety Notes and Warning Messages
The unit uses dangerous mains voltage. Leave servicing to skilled personnel only and do not insert anything into the air vents. Inexpert handling may result in electric shock.
During operation, there may be a hazard of contact with a dangerous voltage of up to 100 V at the speaker terminals. Always switch off the amplifier before making or changing any connections.
Do not operate the unit and disconnect the mains plug from the socket immediately if the unit or the mains cable is visibly damaged; if a defect might have occurred after the unit was dropped or suffered a similar accident, if malfunctions occur. In any case, the unit must be repaired by skilled personnel.
The unit is suitable for indoor use only. Protect it against dripping water and splash water, high air humidity and heat (admissible ambient temperature range: 0 - 40 °C).
Never pull the mains cable to disconnect the mains plug from the socket, always seize the plug.
The heat generated inside the unit must be dissipated by air circulation; never cover the air vents of the housing.
If the unit is to be put out of operation permanently, take it to a local recycling plant for a disposal which is not harmful to the environment.

About

High-power mono PA amplifier
  • 1 x 960 W
  • Additional, adjustable priority input with switchable priority function
  • 100 V slave input for inserting the amplifier into a 100 V speaker line
  • Switchable 400 Hz high-pass filter 6 dB/oct.
  • 2 insertion facilities on the rear panel for optional modules with the following features:
  • PA-6FD: fault detection module
  • PA-6FM: fault monitoring module
  • Connection for external on/off switch (remote start)
  • Temperature-controlled fan, continuously adjustable
  • LED indication for fault, protect, clip, signal, priority
  • Mains operation or 24 V emergency power operation
Manufacturer information:
MONACOR INTERNATIONAL GmbH & Co. KG
Konsul-Smidt-Str. 68
28217 Bremen
Germany
info@monacor.com
Safety Notes and Warning Messages
The unit uses dangerous mains voltage. Leave servicing to skilled personnel only and do not insert anything into the air vents. Inexpert handling may result in electric shock.
During operation, there may be a hazard of contact with a dangerous voltage of up to 100 V at the speaker terminals. Always switch off the amplifier before making or changing any connections.
Do not operate the unit and disconnect the mains plug from the socket immediately if the unit or the mains cable is visibly damaged; if a defect might have occurred after the unit was dropped or suffered a similar accident, if malfunctions occur. In any case, the unit must be repaired by skilled personnel.
The unit is suitable for indoor use only. Protect it against dripping water and splash water, high air humidity and heat (admissible ambient temperature range: 0 - 40 °C).
Never pull the mains cable to disconnect the mains plug from the socket, always seize the plug.
The heat generated inside the unit must be dissipated by air circulation; never cover the air vents of the housing.
If the unit is to be put out of operation permanently, take it to a local recycling plant for a disposal which is not harmful to the environment.

Specifications

Peak output power 960 W
Power rating 960 W
Power rating at 100 V 960 W
Power rating at 70 V 960 W
Output impedance 75 V/5.6 Ω, 85 V/7.2 Ω, 100 V/10 Ω
Channels 1
Inputs 0.775 V/60 kΩ, bal.
Frequency range 35-20,000 Hz
S/N ratio > 100 dB
THD < 0.4%
Power supply ˜ 230 V/50 Hz/2,600 VA,

DC 24 V/80 A

Mains voltage ~ 230 V
Mains frequency 50 Hz
Power consumption, operation 2,600 VA
Standby current DC 24 V
Operating voltage (possible alternative) 80 A
Admiss. ambient temp. 0-40 °C
Width 483 mm
Height 133 mm
Depth 374 mm
Rack units, RU 3
Weight 25 kg
Connections screw contacts (inputs)

screw contacts (speakers)

Packaging dimensions (W x H x L) 0.54 x 0.21 x 0.48 m
Gross weight 28.26 kg
Net weight 26.3 kg
EAN code 4007754203967
Net weight 26.3 kg

Accessories for PA-1960

Intended use:
audio
Connectors:
1 x 3-pole XLR inline jack,

1 x open cable ends

Length:
1 m
Order no.: 1000617
Adapter cable, XLR inline jack, 1 m
Description:
fault detection module
Suitable for:
PA-6240, PA-6480, PA-6600, PA-1960
Admiss. ambient temp.:
0-40 °C
Order no.: 0172300
Fault detection module
Description:
fault monitoring module
Suitable for:
PA-6240, PA-6480, PA-6600, PA-1960
Admiss. ambient temp.:
0-40 °C
Order no.: 0172310
Fault monitoring module

Services

SERVICE
Product & Purchasing Advice
SERVICE
Technical project management
SERVICE
Training at the MONACOR Academy
Contact
You can send us your question or request here.